Water Temperature Control Units
TT-168
TT-168 E, TT-168 H: For use with water up to 90ºC or oil up to 150ºC. TT-168 E/A, TT-168 H/A: For use with water up to 90ºC for larger moulds.
- Automatic mould drain
- Leakstopper – operation in pressure or vacuum mode
- Self-optimising microprocessor controller with digital display of set and actual temperature
- Level control – audible pre-shutdown warning
- Automatic temperature control – audible alarm sounds when unit deviates outside 5ºC preset (adjustable)
- Automatic water refill (not for oil) - time limited to prevent over-filling due to defective hoses
- Connection for optional external thermocouple
- Limescale-free heat exchanger
- Heating switchable in stages – switchable from 6 kW oil operation to 12 kW water operation (TT-168 E and TT-168 H only)
Model: | TT-168E and TT-168H | TT168E/A and TT168H/A |
Heating capacity: |
12 KW for water operation switchable in stages 3/9/12kW switchable for 6 kW oil operation in 3 + 3 kW |
18 kW for water operation switchable in stages 6/12/18 kW |
Temperature range: | with water up to 90º C with oil up to 150º C |
with water up to 90º C |
Control: | self-optimising microprocessor controller with digital display of set and actual temperatures | self-optimising microprocessor controller with digital display of set and actual temperatures |
Flow Control: | Electronic with digital display and automatic control of minimum flow. | |
Cooling Capacity: | 20,000 kcal/h at 90º C (also available on request with double heat exchanger) | 20,000 kcal/h at 90º C (also available on request with double heat exchanger) |
Pump capacity pressure mode: |
Max 4.0 bar / Max 8.0 bar Max .75 l/min / Max .75 l/min |
Max 4.0 bar / Max 8.0 bar Max .75 l/min / Max .75 l/min |
Vacuum mode: | max 8m H2O (water column) | |
Unit Contents: | min 16 litres / max 20 litres | |
Connections: | medium: 1/2" female thread cooling water: 3/8" male thread | |
Dimensions: | L 660 x W 305 x H 765 mm incl. castors and handles | |
Weight: | approx 65kg | |
Colour: | silver grey RAL 7001 |
- Level control provides auto dry run protection
- Separate mechanical safety thermostat
- Temperature limiter installed in the controller
- Motor protection switch, transformer, insulation
- Audible alarm in case of failure